| Radial Leaded PPTC - FRHV
Series
※
RoHS Compliant
/
(Lead
Free) Available
|
| |
|
Application: |
Telecommunication and Data transmitting |
| Product Features: |
Low hold current, Solid state
Radial-leaded product ideal for up to 100V/250V/600V |
| Operation Current: |
0.08 A~0.18A |
| Maximum Voltage: |
100V/250VDC |
| Max. Interrupt
Voltage: |
250V/600V |
| Temperature Range: |
-40°C to 85°C |
| Agency Recognition: |
UL(E211981) ,C-UL(E211981)
TÜV (R50138901)
*UL497A |
|
| |
|
|
| |
Part
Number
|
Hold
Current |
Trip
Current |
Max. Time
To Trip |
Max.
Current |
Max. Oper.
Voltage |
Max. Int.
Voltage |
Typical
Power |
Resistance
|
|
|
RMIN |
R1MAX |
|
|
Current |
Time |
|
IH, A
|
IT, A |
A |
Sec |
IMAX, A |
VMAX,
VDC
|
VI-MAX,V |
Pd, W
|
Ohms |
Ohms
|
|
FRH080-250UVF
|
0.08 |
0.16 |
0.35 |
4.0 |
3.0 |
100 |
250 |
1.0 |
14.0 |
33.0 |
|
|
FRH080-250VF |
0.08 |
0.16 |
0.35 |
4.0 |
3.0 |
100 |
250 |
1.0 |
14.0 |
33.0 |
|
|
FRH110-250UVF |
0.11 |
0.22 |
1.00 |
2.0 |
3.0 |
100 |
250 |
1.0 |
5.0 |
16.0 |
|
|
FRH110-250VF |
0.11 |
0.22 |
1.00 |
2.0 |
3.0 |
100 |
250 |
1.0 |
5.0 |
16.0 |
|
|
FRH120-250UVF |
0.12 |
0.24 |
1.00 |
2.0 |
3.0 |
100 |
250 |
1.0 |
6.0 |
16.0 |
|
|
FRH120-250VF |
0.12 |
0.24 |
1.00 |
2.0 |
3.0 |
100 |
250 |
1.0 |
4.0 |
16.0 |
|
|
FRH145-250UVF |
0.15 |
0.29 |
1.00 |
2.5 |
3.0 |
100 |
250 |
1.0 |
3.5 |
12.0 |
|
|
FRH145-250VF |
0.15 |
0.29 |
1.00 |
2.5 |
3.0 |
100 |
250 |
1.0 |
3.0 |
12.0 |
|
|
FRH180-250UVF |
0.18 |
0.65 |
1.50 |
10.0 |
10.0 |
100 |
250 |
1.5 |
0.8 |
4.0 |
|
|
FRH180-250VF |
0.18 |
0.65 |
1.50 |
11.0 |
10.0 |
100 |
250 |
1.5 |
0.8 |
4.0 |
|
|
FRH180-250XF |
0.18 |
0.65 |
3.00 |
2.0 |
10.0 |
100 |
250 |
1.5 |
0.8 |
4.0 |
|
|
FRH150-600VF |
0.15 |
0.30 |
1.00 |
5.0 |
3.0 |
250 |
600 |
1.0 |
6.0 |
22.0 |
|
|
FRH150-600MF |
0.15 |
0.30 |
1.00 |
3.0 |
3.0 |
250 |
600 |
1.0 |
6.0 |
17.0 |
|
|
FRH160-600VF |
0.16 |
0.32 |
1.00 |
7.0 |
3.0 |
250 |
600 |
1.0 |
4.0 |
18.0 |
|
|
| |
|
IH=Hold
current-maximum current at which the device will not trip at 23℃
still air.
IT=Trip
current-maximum current at which the device will always trip at 23℃
still air.
V
MAX=Maximum
operating voltage at which the device can withstand without damage
at its rated current.
VI
-MAX
= Maximum interrupt voltage device can withstand for short period of
time. (Not for long term.)
I
MAX=
Maximum fault current device can withstand without damage at rated
voltage (V
MAX).
Pd=Typical power dissipated from device when in the tripped state in
23℃ still air
environment.
RMIN=Minimum
device resistance at 23℃.
R1MAX=Maximum
device resistance at 23℃
1 hour after tripping .
Physical specifications:
Lead material: FRH080-250VF ~ FRH180-250VF Tin plated copper,22 AWG.
FRH150-600VF ~ FRH160-600VF Tin plated copper,22 AWG.
Soldering characteristics:MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy ,meet UL 94 V-0
requirement.
NOTE : All FRHV products are
designed to assist equipment to pass ITU,
UL60950, GR1089 and TIA-968-A specification.
* FRH150-600VF, FRH150-600MF,
FRH160-600VF meet UL497A overvoltage test requirement.
CAUTION : FRH devices are not intended for continous use of Line
Voltage such as 120 VAC~ 240VAC and
above.
|
|
| |
 |
 |
 |
Lead Size: 22AWG, Ø 0.65 mm
Diameter |
Lead Size: 22AWG, Ø 0.65 mm
Diameter |
|
Part
Number |
Fig |
A |
B |
C |
D |
E |
|
Maximum |
Maximum |
Typical |
Minimum
|
Maximum |
|
FRH080-250UVF |
1 |
5.1 |
9.1 |
5.0 |
4.7 |
3.8 |
|
FRH080-250VF |
1 |
5.8 |
9.6 |
5.0 |
4.7 |
4.6 |
|
FRH110-250UVF |
1 |
5.9 |
9.4 |
5.0 |
4.7 |
3.8 |
|
FRH110-250VF |
1 |
6.8 |
9.9 |
5.0 |
4.7 |
4.6 |
|
FRH120-250UVF |
2 |
6.0 |
10.0 |
5.0 |
4.7 |
3.8 |
|
FRH120-250VF |
2 |
6.5 |
11.0 |
5.0 |
4.7 |
4.6 |
|
FRH145-250UVF |
2 |
6.0 |
10.0 |
5.0 |
4.7 |
3.8 |
|
FRH145-250VF |
2 |
6.5 |
11.0 |
5.0 |
4.7 |
4.6 |
|
FRH180-250UVF |
2 |
10.4 |
12.6 |
5.0 |
4.7 |
3.8 |
|
FRH180-250VF |
2 |
10.9 |
12.6 |
5.0 |
4.7 |
4.6 |
|
FRH180-250XF |
1 |
9.0 |
12.0 |
5.0 |
4.7 |
3.8 |
|
FRH150-600VF |
2 |
13.5 |
12.6 |
5.0 |
4.7 |
6.0 |
|
FRH150-600MF |
2 |
9.0 |
12.5 |
5.0 |
4.7 |
4.6 |
|
FRH160-600VF |
2 |
16.0 |
12.6 |
5.0 |
4.7 |
6.0 |
|
|
| |
 |
| |
|
| |
 |
| |
A=FRH080-250UVF & FRH080-250VF
B=FRH110-250UVF & FRH110-250VF
C=FRH120-250UVF & FRH120-250VF
D=FRH145-250UVF & FRH145-250VF
E=FRH180-250UVF & FRH180-250VF
F=FRH150-600VF
G=FRH160-600VF |
|
|
H =
FRH180-250XF
I = FRH150-600MF
|
 |
|
| |


|
| |
 |
| |
|
P/N |
Pcs /Bag |
Reel/Tape |
|
FRH080-250UVF |
300 |
1.5K |
|
FRH080-250VF |
300 |
1.5K |
|
FRH110-250UVF |
300 |
1.5K |
|
FRH110-250VF |
300 |
1.5K |
|
FRH120-250UVF |
300 |
1.5K |
|
FRH120-250VF |
300 |
1.5K |
|
FRH145-250UVF |
300 |
1.5K |
|
|
|
P/N |
Pcs /Bag |
Reel/Tape |
|
FRH145-250VF |
300 |
1.5K |
|
FRH180-250UVF |
300 |
1.2K |
|
FRH180-250VF |
200 |
1.2K |
|
FRH180-250XF |
200 |
1.5K |
|
FRH150-600VF |
100 |
600 |
|
FRH150-600MF |
100 |
1.5K |
|
FRH160-600VF |
100 |
600 |
|
|
| |
| Warning: |
- Operation beyond the specified maximum ratings or improper use
may result in damage and possible electrical arcing and/or flame.
- PPTC device are intended for occasional overcurrent protection.
Application for repeated overcurrent condition and/or prolonged
trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent. Prolonged
contact will damage the device performance.
|
| |
All the specifications are subject to change
without previous notice.
|