Radial Leaded PPTC - FRHV Series

                                                                                         RoHS Compliant / (Lead Free) Available

 

 
Application: Telecommunication and Data transmitting
Product Features: Low hold current, Solid state
Radial-leaded product ideal for up to 100V/250V/600V
Operation Current: 0.08 A~0.18A
Maximum Voltage: 100V/250VDC
Max. Interrupt Voltage: 250V/600V
Temperature Range: -40°C to 85°C
Agency Recognition: UL(E211981) ,C-UL(E211981)
TÜV (R50138901)
*UL497A

 

 
 

Part

Number

Hold

Current

Trip

Current

Max. Time

To Trip

Max.

Current

Max. Oper.

Voltage

Max. Int.

Voltage

Typical

Power

Resistance

 

RMIN

R1MAX

Current

Time

 

IH, A

IT, A

A

Sec

IMAX, A

VMAX, VDC

VI-MAX,V

Pd, W

Ohms

Ohms

FRH080-250UVF

0.08

0.16

0.35

4.0

3.0

100

250

1.0

14.0

33.0

 

FRH080-250VF

0.08

0.16

0.35

4.0

3.0

100

250

1.0

14.0

33.0

 

FRH110-250UVF

0.11

0.22

1.00

2.0

3.0

100

250

1.0

5.0

16.0

 

FRH110-250VF

0.11

0.22

1.00

2.0

3.0

100

250

1.0

5.0

16.0

 

FRH120-250UVF

0.12

0.24

1.00

2.0

3.0

100

250

1.0

6.0

16.0

 

FRH120-250VF

0.12

0.24

1.00

2.0

3.0

100

250

1.0

4.0

16.0

 

FRH145-250UVF

0.15

0.29

1.00

2.5

3.0

100

250

1.0

3.5

12.0

 

FRH145-250VF

0.15

0.29

1.00

2.5

3.0

100

250

1.0

3.0

12.0

 

FRH180-250UVF

0.18

0.65

1.50

10.0

10.0

100

250

1.5

0.8

4.0

 

FRH180-250VF

0.18

0.65

1.50

11.0

10.0

100

250

1.5

0.8

4.0

 

FRH180-250XF

0.18

0.65

3.00

2.0

10.0

100

250

1.5

0.8

4.0

 

FRH150-600VF

0.15

0.30

1.00

5.0

3.0

250

600

1.0

6.0

22.0

 

FRH150-600MF

0.15

0.30

1.00

3.0

3.0

250

600

1.0

6.0

17.0

 

FRH160-600VF

0.16

0.32

1.00

7.0

3.0

250

600

1.0

4.0

18.0

 

 

 

IH=Hold current-maximum current at which the device will not trip at 23 still air.
I
T=Trip current-maximum current at which the device will always trip at 23 still air.
V
MAX=Maximum operating voltage at which the device can withstand without damage at its rated current.
V
I -MAX = Maximum interrupt voltage device can withstand for short period of time. (Not for long term.)
I
MAX= Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated from device when in the tripped state in 23 still air environment.
R
MIN=Minimum device resistance at 23.
R1
MAX=Maximum device resistance at 23 1 hour after tripping .
Physical specifications:
Lead material: FRH080-250VF ~ FRH180-250VF Tin plated copper,22 AWG.
                           FRH150-600VF ~ FRH160-600VF Tin plated copper,22 AWG.
Soldering characteristics:MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy ,meet UL 94 V-0 requirement.

NOTE : All FRHV products are designed to assist equipment to pass ITU, UL60950, GR1089 and TIA-968-A specification.

             * FRH150-600VF, FRH150-600MF, FRH160-600VF meet UL497A overvoltage test requirement.

CAUTION : FRH devices are not intended for continous use of Line Voltage such as 120 VAC~ 240VAC and above.

 

 

 
Lead Size: 22AWG,
Ø 0.65 mm Diameter
Lead Size: 22AWG,
Ø 0.65 mm Diameter

Part

Number

Fig

A

B

C

D

E

Maximum

Maximum

Typical

Minimum

Maximum

FRH080-250UVF

1

5.1

9.1

5.0

4.7

3.8

FRH080-250VF

1

5.8

9.6

5.0

4.7

4.6

FRH110-250UVF

1

5.9

9.4

5.0

4.7

3.8

FRH110-250VF

1

6.8

9.9

5.0

4.7

4.6

FRH120-250UVF

2

6.0

10.0

5.0

4.7

3.8

FRH120-250VF

2

6.5

11.0

5.0

4.7

4.6

FRH145-250UVF

2

6.0

10.0

5.0

4.7

3.8

FRH145-250VF

2

6.5

11.0

5.0

4.7

4.6

FRH180-250UVF

2

10.4

12.6

5.0

4.7

3.8

FRH180-250VF

2

10.9

12.6

5.0

4.7

4.6

FRH180-250XF

1

9.0

12.0

5.0

4.7

3.8

FRH150-600VF

2

13.5

12.6

5.0

4.7

6.0

FRH150-600MF

2

9.0

12.5

5.0

4.7

4.6

FRH160-600VF

2

16.0

12.6

5.0

4.7

6.0

 

 
 

 

 

 
 

 

A=FRH080-250UVF & FRH080-250VF

B=FRH110-250UVF & FRH110-250VF

C=FRH120-250UVF & FRH120-250VF

D=FRH145-250UVF & FRH145-250VF

E=FRH180-250UVF & FRH180-250VF 

F=FRH150-600VF

G=FRH160-600VF

 

H = FRH180-250XF

I = FRH150-600MF

 

 

 

 
 

P/N

Pcs /Bag

Reel/Tape

FRH080-250UVF

300

1.5K

FRH080-250VF

300

1.5K

FRH110-250UVF

300

1.5K

FRH110-250VF

300

1.5K

FRH120-250UVF

300

1.5K

FRH120-250VF

300

1.5K

FRH145-250UVF

300

1.5K

 

 

P/N

Pcs /Bag

Reel/Tape

FRH145-250VF

300

1.5K

 FRH180-250UVF

300

1.2K

FRH180-250VF

200

1.2K

FRH180-250XF

200

1.5K

FRH150-600VF

100

600

FRH150-600MF

100

1.5K

FRH160-600VF

100

600

 


 
Warning:
  1. Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical arcing and/or flame.
  2. PPTC device are intended for occasional overcurrent protection. Application for repeated overcurrent condition and/or prolonged trip are not anticipated.
  3. Avoid contact of PPTC device with chemical solvent. Prolonged contact will damage the device performance.

All the specifications are subject to change without previous notice.